What's included

  • Soil and load considerations
  • Foundation and frame design
  • Reinforcement detailing
  • Structural drawings for site use

Overview

Structural Design with BHK99

Structural design decides how a building carries its own weight, the people and contents inside it, and wind and earthquake forces, and how it passes all of that safely into the ground. BHK99's structural engineers design foundations, columns, beams, slabs and steel frames to the relevant Indian Standard codes, using your soil information and the loads your building will actually carry rather than rules of thumb.

Safety comes first, and within that we look for a sensible use of steel and concrete. An over-designed frame wastes money and an under-designed one is not acceptable. Spans, column grid and member sizes are worked out together with the architecture, so the structure supports the plan instead of fighting it, and beams do not land where a window or a door should be.

The output is a numbered set of structural drawings issued for construction by BHK99's engineers, with reinforcement details that bar-benders and masons can follow, plus site clarifications as work proceeds. We also assess existing buildings: checking their condition, investigating cracks, judging whether another floor can be added, and proposing strengthening where it is needed. Each assessment ends in a written report, so you have a clear record of what was found and what we recommend.

Who it's for

  • Families building a home

    A house designed properly for its soil and loads, including a floor you may add in future.

  • Commercial and industrial owners

    Buildings with longer spans, heavier loads, mezzanines or steel sheds that need careful framing.

  • Architects and contractors

    Teams with the architecture ready who need structural design and detailing coordinated to it.

  • Owners of existing buildings

    Anyone concerned about cracks, planning an extra floor or wanting to know the condition of an older structure.

Scope of work

  • Soil and load considerations
  • Foundation and frame design
  • Reinforcement detailing
  • Structural drawings for site use

Suited for

  • New construction
  • Floor additions
  • Industrial structures

Every project is quoted after we understand your site and requirements. Share a few details and our team will call you.

Step by step

How we deliver this

  1. 1

    Soil & load study

    Foundation design starts from your soil test where one exists, and from the loads the structure will actually carry — not a generic assumption.

  2. 2

    Structural system decisions

    Framing type, spans and column grid are decided to balance safety with how much steel and concrete the structure actually needs.

  3. 3

    Foundation & frame design

    Footings, columns, beams and slabs are designed and checked against the loads and the soil.

  4. 4

    Reinforcement detailing

    Every column, beam and slab is detailed with exact bar sizes, spacing and bends — what the bar-bender and mason actually follow on site.

  5. 5

    Structural drawings issued for construction

    A complete, numbered drawing set (GFC — good for construction) is handed to the site team.

  6. 6

    Site support during execution

    We stay available to resolve site queries against the structural drawings as work proceeds.

What you receive

  • Foundation and frame design calculations
  • Column, beam and slab reinforcement detailing
  • Structural drawings issued for construction
  • Site clarifications during execution

Materials & quality

Standards & inputs

Structural safety rests on correct inputs, recognised codes and careful checking. These are the basics behind every structural design we issue.

  • Soil investigation

    A soil test report gives the bearing capacity and soil type the foundation is designed for. Where none exists, we explain why one is advisable and what the design would otherwise have to assume.

  • Indian Standard codes

    Design follows the relevant codes, such as IS 456 for reinforced concrete, IS 875 for loads, IS 1893 for earthquake design, IS 13920 for ductile detailing and IS 800 for structural steel.

  • Written design basis

    Seismic zone, wind conditions, material grades and the use of each floor are fixed in writing before analysis begins.

  • Engineer-reviewed analysis

    The frame is analysed in structural software and the results are reviewed by an engineer, not accepted without checking.

  • Coordination with architecture

    Column positions, beam depths and slab levels are checked against the architectural drawings before issue, so the two sets agree.

  • Numbered drawing issues

    Each structural sheet carries a number, revision mark and date. When something changes, the revised sheet is reissued and the old one marked superseded.

Typical timeline

Indicative durations for a typical residential or small commercial building once the architectural plans are fixed. Larger or unusual structures take longer; the schedule is agreed in writing.

  1. Inputs & design basis

    Architectural drawings, soil report and the use of each floor are collected, and the design basis is agreed.

    1–2 weeks

  2. Structural scheme

    Column grid, framing system and foundation type are set and checked against the architecture.

    1–2 weeks

  3. Analysis & design

    Members are analysed and designed for gravity, wind and earthquake loads.

    2–3 weeks

  4. Detailing & drawings

    Foundation, column, beam and slab drawings with reinforcement details are prepared and checked.

    2–4 weeks

  5. Site support

    Clarifications and, where agreed, visits at key stages such as footing and slab reinforcement.

    ongoing

Indicative ranges only. Your project's schedule is agreed in writing once the design and scope are final.

What changes the duration

  • Building size, number of floors and spans
  • Whether a soil test report is available
  • Whether the architecture is fixed or still changing
  • Steel or pre-engineered structures that need fabrication coordination
  • Special loads such as water tanks, machinery or cranes
  • For existing buildings: access, testing and the extent of damage

Project Enquiry

Tell us about your construction requirements and our team will get in touch.

Our Locations

We serve key locations with a local, on-ground approach.

Questions we often hear

Do I really need a soil test?

For most new buildings we recommend one. The soil's bearing capacity and type decide the size and depth of the foundation. Designing without it means relying on assumptions that may be too cautious, which costs more, or not cautious enough, which is a safety risk. For small single-storey work we discuss what is reasonable for your site.

Which codes do you design to?

We design to the relevant Indian Standard codes. Commonly used ones include IS 456 for reinforced concrete, IS 875 for dead, live and wind loads, IS 1893 for earthquake resistance, IS 13920 for ductile detailing in seismic areas and IS 800 for steel structures. The design basis for your project lists the codes applied.

Does my building need earthquake design?

Yes. Every location in India falls in a seismic zone defined by IS 1893, and the structure is designed for the zone that applies to your site. Earthquake design matters even in lower-risk zones, and good detailing at beam-column joints matters as much as the member sizes themselves.

What drawings will I receive?

Typically a foundation layout with details, a column layout and schedule, beam and slab layouts for each floor, staircase and water-tank details, and reinforcement details with bar sizes and spacing. Bar bending schedules can be added where agreed. Each sheet is numbered and revised in a controlled way.

Can I add another floor later?

If you plan for it now, the foundation, columns and beams can be designed for the extra floor from the start, which is far simpler than strengthening later. For an existing building, we first assess the structure and any original drawings before advising whether an additional floor is feasible and what it would need.

Why do your column sizes differ from what my mason suggests?

Masons often work from rules of thumb based on earlier buildings. Column sizes depend on the loads, spans, number of floors, soil and earthquake zone of your particular building. We are happy to walk you and your contractor through the reasoning behind the design, so everyone on site understands it.

Do you visit the site during construction?

Site support is part of the service, as agreed in the proposal. We recommend checks before concreting key elements such as footings, columns and slabs, so the reinforcement can be compared with the drawings while it is still visible and can still be corrected.